Production Description

Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signal control of current signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices.

Hall current sensors are widely applicable for acquisition and feedback in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature quick response, a wide range of measurements, high precision, strong overload capacity, good linearity and excellent anti-interference performance.


Appearance






Parameters

Technical parameters

Data

Split/closed open-loop

Hall (true RMS)

Output

Nominal value

Voltage: ±5V/±4V

Current: 4-20mA

Zero offset voltage (current)

Voltage: ±20mV

Current:±0.05mA

Offset voltage (current) drift

Voltage: ≤±1.0mV/℃

Current:±0.04mA/ ℃

Linearity

≤0.2%FS

Power voltage

DC±15V

DC 24V

Bandwidth

0-20kHz


Response time

≤5us

≤1ms

Dielectric strength

Permissible 2500VAC between input/ output and power supply at the power frequency

Accuracy class

1.0

Ambient conditions

Temperature

Operating temperature:-25℃-+70℃; storage temperature: -40℃-+85℃

Humidity

≤95%RH, no dew, no aggressive gas

Altitude

≤3500m


Dimension
Fig.1 Fig.2


Size Specification

Outline size

Through size

Mounting size

Figure

W

H

D

a

e

Φ

M

N

AHKC-EKA

60

64

16

/

/

20

47

/

Fig.1

AHKC-EKAA

60

64

16

/

/

20

47

/

Fig.1

AHKC-EKDA

60

64

16

/

/

20

47

/

Fig.1

AHKC-EKB

100

102

24

/

/

40

80

/

Fig.1

AHKC-EKBA

100

102

24

/

/

40

80

/

Fig.1

AHKC-

EKBDA

100

102

24

/

/

40

80

/

Fig.1

AHKC-K

127

63

25

64

16

/

/

30

Fig.2

AHKC-KAA

127

63

25

64

16

/

/

30

Fig.2

AHKC-KDA

127

63

25

64

16

/

/

30

Fig.2

AHKC-H

149

79

25

82

32

/

/

46

Fig.2

AHKC-KA

176

95.5

29

104

36

/

/

60

Fig.2

AHKC-HB

204

111.5

29

132

52

/

/

48 ×

2

Fig.2


Current Ratio

Specification

Rated current

Power supply

Rated output

Measuring aperture (mm)

Precision degree

AHKC-EKA

0~(20-500)A

±15V

5V

φ 20

1

AHKC-EKAA

DC 0~(50-500)A

12V/24V

4~20mA

φ 20

1

AHKC- EKDA

AC 0~(50-500)A

12V/24V

4~20mA

φ 20

1

AHKC-EKB

0~(200-1000)A

±15V

5V

φ 40

1

AHKC- EKBA

DC 0~(200- 1000)A

12V/24V

4~20mA

φ 40

1


AHKC- EKBDA

AC 0~(200~ 1000)A

12V/24V

4~20mA

φ 40

1

AHKC-K

0~(400-2000)A

±15V

5V

64×16

1

AHKC- KAA

DC 0~(400- 2000)A

12V/24V

4~20mA

64×16

1

AHKC- KDA

AC 0~(400- 2000)A

12V/24V

4~20mA

64×16

1

AHKC-H

0~(500-3000)A

±15V

5V

82×32

1

AHKC-KA

0~(500-5000)A

±15V

5V

104×36

1

AHKC-HB

0~(2000-20000)A

±15V

5V

132×52

1

Note: Rated current unlabeled indicates that AC and DC input current can be measured, please specify when ordering.


Closed Hall Current Sensor

Fig.1

Fig.2


Size Specification

Outline size(mm)

Through size(mm)

Mounting

size(mm)

Figure

W

H

D

a

e

Φ

M

N

AHKC-E

53

72

16

/

/

21

47

/

Fig.1

AHKC-LT

90

73.5

25

/

/

32.5

74.5

71

Fig.1

AHKC-BS

43

32.5

19

20.5

10.5

/

/

/

Fig.2

AHKC-BSA

43

32.5

19

20.5

10.5

/

/

/

Fig.2

AHKC-F

74

57

22

43

13

/

/

22

Fig.2

AHKC-FA

94

60.5

26.5

52

15

/

83

28

Fig.2

AHKC-HAT

94

76.5

24

52.5

32

/

83

28

Fig.2


Current Ratio

Specification

Rated current

Power supply

Rated output

Measuring aperture (mm)

Accuracy

AHKC-E

0~(20-500)A

±15V

5V

φ 20

1

AHKC-LT

0~(100-800)A

±15V

5V

φ 32.5

1

AHKC-BS

0~(20-500)A

±15V

5V

20.5*10.5

1

AHKC-BSA

DC 0~(50-500)A

12V/15V/24 V

4~20mA

20.5*10.5

1

AHKC-F

0~(200-1000)A

±15V

5V

43*13

1

AHKC-FA

0~(200-1500)A

±15V

5V

52*15

1

AHKC-HAT

0~(400-2000)A

±15V

5V

52*32

1

Note: Rated current unlabeled indicates that AC and DC input current can be measured, please specify when ordering.

Quotation

http://www.acrel-global.com/